Evo® Cortical Electrode

Cortical or subdural electrodes are used in electrocorticography (ECoG) or intracranial electroencephalography (iEEG) surgeries to monitor, record and stimulate the surface of the brain for less than 30 days.

Our Evo® Сortical electrode portfolio consists of various contact configurations of strip and grid electrodes.

CAUTION: U.S. Federal law restricts this device to sale by, or on the order of, a physician.  

Evo® Cortical Electrode

Cortical or subdural electrodes are used in electrocorticography (ECoG) or intracranial electroencephalography (iEEG) surgeries to monitor, record and stimulate the surface of the brain for less than 30 days.

Our Evo® Сortical electrode portfolio consists of various contact configurations of strip and grid electrodes.

CAUTION: U.S. Federal law restricts this device to sale by, or on the order of, a physician.  

NEUROONE PORTFOLIO

The Evo® Cortical Electrode Advantage

Decreased Immunological Response

The Evo® Cortical Electrode is over 7 times thinner than a silicone electrode. The flexibility and reduced volume should reduce pain and edema. (2)

The Evo’s polyimide substrate has properties like increased flexibility, reduced volume, and decreased immunological response, which should reduce signal artifacts. (3)

Single Tail Design

The single thin tail design allows the implanted electrode tail to be tunneled through one incision which should reduce infection risk and procedure time. (1,2)

Reduced Cable Management 

A disposable cable assembly is sent with each Evo® Cortical Electrode as an electrode kit, removing the need to source the correct cables for each electrode being used in surgery. Also, hospital resources are freed from the management of sterilizing and storing individual electrode cable assemblies.

  1. WORRELL,G. ET. AL. DECEMBER 2019. COMMERCIAL SCALE PRODUCTION OF THIN-FILM ELECTRODE ARRAYS FOR CLINICAL INTRACRANIAL EEG. ((ABST. 1.154), 2019. AMERICAN EPILEPSY SOCIETY.

  2. BOWER R, ET AL. DECEMBER 2017. DEVELOPMENT OF POLYIMIDE ELECTRODES FOR HIGH-RESOLUTION INTRACRANIAL EEG RECORDINGS. (ABST. 1.060) 2017. AMERICAN EPILEPSY SOCIETY.

  3. BOWER R, ET AL. DECEMBER 2017. MULTI-RESOLUTION INTRACRANIAL EEG RODENT RECORDING SYSTEM. (ABST. 2.062) 2017. AMERICAN EPILEPSY SOCIETY.

How NeuroOne's

Thin Film Electrode

Technology is Different

In comparison to other currently available technologies, our electrodes are manufactured with polyimide thin film. Our electrodes are designed to reduce trauma to the brain by allowing a less invasive implant due to the flexibility, thinness and reduced weight of the electrode.

Furthermore, the potential to significantly increase the resolution of brain recordings may enable the usage of powerful computing techniques, such as machine learning and artificial intelligence.

Specifications

Number of Contacts

2 - 16

Contact Spacing

10mm 

Contact Size

3mm

Electrode Contact Material

Platinum

Electrode Substrate Material

Polyimide

Thickness

0.08mm

Weight

0.05 grams

Tail Length

12.70 inches

Disposable Cables

Proprietary cable assembly for the Evo® Cortical Electrode with a zero force connection box and standard DIN42802 touch-proof connectors compatible with standard headboxes.

See the Instructions for Use for additional information (e.g. Description, Indications for Use, Contraindications, Warnings, Potential Adverse Events, etc.) 

Caution